Batteries for Hyperloop Pods and Prototype Vehicles: High-Voltage Power for Platforms That Exist Only Once
A hyperloop pod battery, a prototype EV pack or the power source for a record vehicle has a problem a production pack never has. There will be one of it. Nobody has built it before, the run window is fixed, and the pack must work the first time it is energised. Off-the-shelf modules rarely fit the envelope, the voltage or the discharge rate.
Then the questions start. Which cells survive a 30-second full-power run? How do you cool a pack in a tube with no air? What does the track safety officer need to see before 400 V is switched on inside a sealed structure? This post walks through those questions the way we work through them with a team at the special-purpose battery pack stage.
A hyperloop pod battery sees a power profile no car pack sees
The run is short and brutal. A pod or test sled accelerates at full motor power for tens of seconds, coasts, then brakes. Peak discharge can be many times the pack's one-hour rate, yet the run uses only a fraction of the stored energy. The pack is sized by power, not watt-hours.
Regen pushes energy back in fast. Electric braking returns current to the pack at rates close to the discharge peak. A cell that accepts charge slowly, or a pack already near full, cannot absorb it. The BMS must know the live charge-acceptance limit and tell the motor controller when to hand braking over to friction or eddy-current brakes.
Then it sits. Between runs the pod may wait for hours in a tube being pumped down, neither charging nor discharging. Cycle life barely matters for a platform that will run perhaps fifty times. Power, charge acceptance and predictability are everything.
Why prototype vehicles go to 400 V, and what that does to the cells
Voltage keeps current, and copper, manageable. Hundreds of kilowatts at 48 V would need thousands of amps and busbars the size of the chassis. At 400 V-class the same power flows at a current that automotive contactors, cables and inverters can handle.
Series count is set by voltage; the real choice is the parallel group. A 400 V-class pack is roughly 96 to 110 lithium-ion cells in series. High-drain Li-ion cells give the current but store less energy. NMC energy cells store more but must be worked gently. The C-rate of the run decides. If the peak is 10C or above, high-drain cells built for burst loads are the honest choice. For endurance runs at moderate rate, NMC cells in larger parallel groups may win.
Parallel groups must share current evenly. At high C-rates a few milliohms of interconnect difference shifts current onto one cell, which runs hotter and ages faster. Reinforced interconnects, matched cell resistance at incoming QC and symmetrical busbars make a parallel group behave as one cell. We design high-voltage packs as series-connected modules, each with its own monitoring electronics under a master BMS. The same architecture we describe for eVTOL and electric aircraft packs applies here.
A pack in a vacuum tube has no air to cool it
Convection stops when the pressure drops. In a low-pressure tube the air is too thin to carry heat away. Every joule of loss in cells, busbars and contactors stays in the pack until it conducts to the chassis or radiates.
Thermal mass is the cooling system. For a burst platform, size the cells and module structure so their heat capacity absorbs the run without exceeding cell limits. A pack that starts at 20 °C and finishes at 45 °C has done its job. Module-level thermal management with conduction paths into the chassis gives that heat somewhere to go after the run.
Pre-conditioning sets the starting point. Cells deliver more current and accept regen better when warm. Before a run the pack should be brought to target temperature by controlled discharge, external heating during the wait, or a heater plate. Our packs are rated from −30 °C to +60 °C, but the pre-conditioning plan is what puts the pack in its best window when the run starts.
Outgassing and pressure changes are real. Adhesives, potting, foams and cable jackets release volatiles under vacuum. We select potting and enclosure materials for vacuum exposure and design the vent path so a cell event vents in a controlled direction, not into the module electronics.
Safety inside a sealed test track
Nobody can reach the pod once the tube is closed. Every safety function must work without a human. The HV architecture starts with main contactors on both rails, controlled by the master BMS. A pre-charge circuit brings the inverter's DC-link capacitors up through a resistor before the main contactor closes, so the contacts never see an inrush arc.
Isolation monitoring watches the chassis. It continuously measures resistance between the HV bus and the frame, so a chafed cable or condensation is caught before it becomes a shock hazard. The HV interlock loop is a low-voltage circuit through every connector, cover and the emergency stop. If any point opens, the contactors drop within milliseconds.
Emergency disconnect must be independent. Track rules generally require isolation that does not rely on pod software. A hardwired path from the e-stop and the track's kill signal opens the contactors directly. Cell-level fusing limits what a failed cell can push into its neighbours. Propagation containment between cells and modules keeps one cell event one cell event, long enough for the tube to be vented and the pod recovered. The BMS's role in all this is covered in what a battery management system does.
Telemetry the team needs to see live
The pod controller needs the pack's limits, not just its state. Over CAN the BMS streams every cell voltage, every temperature, pack current, state of charge and state of health at a rate the control loop can use. More useful still are live discharge and charge current limits. The motor controller de-rates power or regen before the BMS has to trip.
The ground station needs the same data. Telemetry should be relayed to the monitoring desk and captured by an on-board data logger. After the run, that log shows whether the pack was thermally or electrically limited, and it is the evidence the safety officer wants before the next run. We define the CAN message set with the team so the pack fits their control stack.
The safety documentation package that gets you onto the track
Competitions and test facilities want evidence before they want the pod. A typical package includes the HV schematic, the cell datasheet with its UN38.3 transport test summary, protection settings, interlock and e-stop logic, the isolation strategy, a failure-mode analysis and end-of-line test records. We prepare the pack-level parts of this package with every one-off build. Documented test records and batch-level traceability ship with the pack.
Standards give the reviewer a shared language. Even where no certification is required, packs designed to support qualification to IEC 62619, IEC 62133 and UN38.3 make the review faster. Reviewers recognise the test names, and that often turns a conditional approval into a green light.
One pack now, a better one next season
Ones and tens are normal quantities for us. Our process runs from requirement capture under NDA through cell selection, electrical, mechanical and thermal design, to a prototype validated on the customer's platform. We build single units for student teams or start-up to work around. Each pack gets incoming cell QC and end-of-line testing as a production unit would.
The modular architecture makes iteration cheap. Next year's pod can reuse the module design and master BMS while changing module count, enclosure or cell type. Firmware, telemetry message sets and safety logic carry over.
The first conversation is a requirement-capture conversation. We ask for the power budget over a full run profile, including regen. We ask for envelope, mass target and mounting interface. We ask about the environment, whether a vacuum tube, a salt flat or a test hall, and how the pod controller and track safety system expect to talk to the pack. Our guide on how to specify a custom battery pack sets out what to bring.
Made in India, engineered for platforms that exist only once
Revogreen Technologies designs and manufactures custom lithium-ion battery packs in Pune, India. Since 2021 we have delivered more than 30,000 batteries to over 100 clients, and we design and build packs from 2S smart formats up to 400 V-class and beyond. For a hyperloop team, a start-up or an R&D lab, that means a partner who can build one pack, test it, document it and support the next iteration. We treat battery, BMS and charger as one system, the approach in our guide to a complete power solution. Our special-purpose packs and ground robotics packs share the same engineering base. Made in India, shipped worldwide.